sp; r1:2.0mm r2:4.0mm 测量数据: ************************************ 1: -376 -283 -113 -196 -137 -73 2: -349 -264 -192 -201 -162 -97 3: -383 -296 -160 -184 -172 -84 4: -310 -267 -251 -193 -142 -110 5: -311 -268 -212 -179 -171 -82 6: -342 -217 -194 -198 -142 -99 7: -363 -203 -144 -184 -162 -87 8: -309 -262 -200 -165 -146 -94 9: -375 -215 -143 -201 -101 -81 10: -336 -271 -204 -190 -181 -96 11: -351 -307 -208 -182 -163 -82 12: -368 -262 -174 -179 -172 -67 ************************************ 计算结果: ------------------------------------------------------------------- σ1(MPa) σ2(MPa) θ(度) 测点 ---------------------- --------------------- ------------- 振前 振后 消除率% 振前 振后 消除率% 振前 振后 ------------------------------------------------------------------- 1: 383.06 203.95 46.8 248.88 143.68 42.3 -8.16 -1.16 2: 388.14 218.80 43.6 311.00 166.31 46.5 2.37 -7.02 3: 406.76 203.92 49.9 294.97 142.42 51.7 -6.20 -18.62 4: 378.38 216.63 42.7 346.61 174.94 49.5 12.30 6.45 5: 362.38 199.58 44.9 313.49 137.71 56.1 -3.74 -19.93 6: 390.34 216.35 44.6 302.34 167.46 44.6 17.29 3.74 7: 386.64 202.17 47.7 268.56 148.05 44.9 12.38 -14.33 8: 355.83 186.52 47.6 301.96 148.19 50.9 -3.92 -12.46 9: 395.45 217.52 45.0 273.96 146.91 46.4 10.39 16.85 10: 381.24 214.39 43.8 316.60 155.21 51.0 -0.43 -19.48 11: 398.71 199.39 50.0 323.69 141.78 56.2 -10.52 -15.90 12: 397.91 195.39 50.9 302.52 122.52 59.5 2.65 -20.59 ------------------------------------------------------------------- 平均: 385.40 206.22 46.5 300.38 149.60 50.2 / / -------------------------------------------------------------------
结论与分析: 使用华云HK2000型振动消除应力设备,第一次时效,击振力12档,转数6322第二次时效,击振力12档,转数6382 ①从表一.阀门通过振动时效在处理过程中其加速度幅值的变化可以看出在第一次时效(图片一)均随着时间的增加而加速度幅值发生变化0.5-5分钟加速度幅值变化的很快/5-14分钟加速度幅值有一定的变化,14分钟以后加速度幅值变动较小了,30分钟后加速度幅值趋于稳定了,而在第二次振动时效在处理过程中其加速度幅值的变化相对较小(图片二)可以看出在第一次振动时效完成后残余应力就趋于稳定了,说明在经过50分钟时效处理,残余应力下降和均化稳定,完全符合“标准”中关于振动时效技术效果的要求。 ②从表二可以看出,测试数据非常均匀整齐,振动处理前主应力为385.40.MPa,而振动处理后主应力为 206.22 MPa,消除率为 46.5 %,超过标准要求。这次VSR处理是合格的。 |